myMectronic
myMectronic

A Premier B2B Part Search

BELDEN 9259010U500 75 Ohm Coax Cable

The Belden 9259 is a 75 Ohm coax cable suitable for a variety of applications, particularly CCTV systems. Constructed with a 22 AWG stranded bare copper conductor, foam polyethylene insulation, a bare copper braid shield (95% coverage), and a durable PVC jacket, this cable provides reliable signal transmission. It meets various industry standards including NEC, CEC, and UL specifications. The cable's operating temperature range is -40°C to +80°C, making it suitable for diverse environments. Its low capacitance and characteristic impedance ensure optimal signal integrity.

Authorized Distributors
Part No:9259 010U500
Stock:0
Inv Date:05-31-2026
Price: N/A
Buy/RFQ:
Part No:9259 010U500
Stock:0
Inv Date:05-30-2026
Price: Unit price: $565.24
Buy/RFQ:
Part No:9259-010-U500
Stock:0
Inv Date:05-30-2026
Price: Unit price: $447.14
Buy/RFQ:
Part No:9259-010-U500
Stock:0
Inv Date:05-30-2026
Price: Unit price: $447.14
Buy/RFQ:

BELDEN 9259010U500 75 Ohm Coax Cable Specifications:

  • Conductor AWG: 22
  • Conductor Stranding: 7x30
  • Conductor Material: BC - Bare Copper
  • Insulation Material: FPE - Foam Polyethylene
  • Insulation Dia. (in.): 0.146
  • Outer Shield Material: Braid, BC - Bare Copper
  • Outer Shield Coverage (%): 95
  • Outer Jacket Material: PVC - Polyvinyl Chloride
  • Overall Nominal Diameter: 0.241
  • Operating Temperature Range: -40°C To +80°C
  • Non-UL Temperature Rating: 80°C
  • Bulk Cable Weight: 33 lbs/1000 ft.
  • Max. Recommended Pulling Tension: 65 lbs
  • Min. Bend Radius/Minor Axis: 2.500 in
  • NEC/(UL) Specification: CM
  • CEC/C(UL) Specification: CM
  • AWM Specification: UL Style 1354
  • EU Directive 2011/65/EU (ROHS II): Yes
  • EU CE Mark: Yes
  • EU Directive 2000/53/EC (ELV): Yes
  • EU Directive 2002/95/EC (RoHS): Yes
  • EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
  • EU Directive 2002/96/EC (WEEE): Yes
  • EU Directive 2003/11/EC (BFR): Yes
  • CA Prop 65 (CJ for Wire & Cable): Yes
  • MII Order #39 (China RoHS): Yes
  • RG Type: 59/U
  • UL Flame Test: UL1685 UL Loading
  • Suitability - Indoor: Yes
  • Plenum (Y/N): No
  • Plenum Number: 89259 or 82259
  • Max. Characteristic Impedance: 75 Ohm
  • m. Inductance (µH/ft): 0.09
  • Capacitance (pF/ft): 17.3
  • VP (%): 78
  • Delay (ns/ft): 1.3
  • DCR @ 20°C (Ohm/1000 ft) - Conductor: 15
  • DCR @ 20°C (Ohm/1000 ft) - Outer Shield: 2.6
  • Attenuation (dB/100 ft.) @ 1 MHz: 0.30
  • Attenuation (dB/100 ft.) @ 5 MHz: 0.65
  • Attenuation (dB/100 ft.) @ 10 MHz: 0.90
  • Attenuation (dB/100 ft.) @ 50 MHz: 2.1
  • Attenuation (dB/100 ft.) @ 100 MHz: 3.0
  • Attenuation (dB/100 ft.) @ 200 MHz: 4.5
  • Attenuation (dB/100 ft.) @ 400 MHz: 6.6
  • Attenuation (dB/100 ft.) @ 700 MHz: 8.9
  • Attenuation (dB/100 ft.) @ 900 MHz: 10.1
  • Attenuation (dB/100 ft.) @ 1000 MHz: 10.9
  • X. Operating Voltage - UL: 300 V RMS

Buy the 9259 010U500 Belden 75 Ohm Coax Cable | myMectronic

Securely purchase the Belden 9259 010U500 coax cable online for reliable performance and fast delivery.

Buy Now

Frequently Asked Questions

Where can I buy BELDEN 9259010U500?

You can click on the BUY or RFQ button to purchase 9259010U500 from an authorized BELDEN distributor.

How do I troubleshoot issues or seek technical support for part 9259010U500?

You can download the 9259010U500 datasheet or visit the BELDEN website for support.

Who is the manufacturer of 9259010U500?

BELDEN

BELDEN Part List

Browse and search other BELDEN parts, locate datasheets and stock

Sponsored by