Carling Technologies' C-Series hydraulic-magnetic circuit breakers provide a robust solution for applications demanding high amperage and voltage capabilities in a compact design. Featuring a unique arc chute design allowing for interrupting capacities up to 10,000 amps, these breakers are available in 1-6 poles, with a wide range of current ratings and voltage options. They are suitable for marine, telecom/datacom, military, renewable energy, and generator/welder applications, and offer features like mid-trip handle styles for visual overload indication. Constructed with a thermoset glass-filled polyester half shell, the C-Series ensures increased mechanical and electrical strength, contributing to reliable performance in demanding environments.
Insulation Resistance: Minimum of 100 Megohms at 500 VDC
Dielectric Strength: UL, CSA: 1960 V 50/60 Hz for one minute
Endurance: 10,000 ON-OFF operations @ 6 per minute
Trip Free: All C-Series circuit breakers will trip on overload
Number of Poles: 1-6 poles ≤ 50A; 1-4 poles @ 51-70A; 1-2 poles 71-100A
Internal Circuit Configuration: Series (with or without auxiliary switch, mid trip & mid trip with alarm switch) Shunt & Relay with current or voltage trip coils, Dual Coil, Switch Only (with or without aux. switch)