E-T-A 1410L210L2F1S025A Single Pole Circuit Breaker

The E-T-A 1410-L210-L2F1-S02-5A is a single-pole thermal circuit breaker engineered for reliable overcurrent protection. Its fast overload switching performance (R-type TO CBE to EN 60934) makes it suitable for protecting sensitive electronics and electrical components. The device features a press-to-reset mechanism and a choice of mounting designs, including PCB and integral options. Typical applications include motors, transformers, solenoids, PCBs, hand-held machines, appliances, and instrumentation. The miniaturized construction minimizes PCB real estate requirements, making it ideal for space-constrained designs.

Authorized Distributors
Source:DigiKey
Part No:1410-L210-L2F1-S02-5A
Stock:1713
Inv Date:06-08-2026
Price: Unit price: $15.36
Buy/RFQ:
Part No:1410-L210-L2F1-S02-5A
Stock:119
Inv Date:06-09-2026
Price: Unit price: $15.36
Buy/RFQ:
Part No:1410-L210-L2F1-S02-5A
Stock:0
Inv Date:06-08-2026
Price: Unit price: $15.36
Buy/RFQ:
Part No:1410-L210-L2F1-S02-5A
Stock:0
Inv Date:06-08-2026
Price: Unit price: $11.96
Buy/RFQ:
Part No:1410-L210-L2F1-S02-5A
Stock:0
Inv Date:06-08-2026
Price: Unit price: $11.96
Buy/RFQ:

E-T-A 1410L210L2F1S025A Single Pole Circuit Breaker Specifications:

  • Voltage rating: AC 240 V; DC 28 V (DC 50 V UL/CSA)
  • Current rating range: 0.63...10 A
  • Auxiliary circuit: 0.2 x INmax. 1 A, AC 250 V
  • Typical life: 300 operations at 2 x IN(-L2...) / 500 operations at 2 x IN(-L1../-G1..)
  • Ambient temperature: -20...+100°C
  • Insulation co-ordination: Rated impulse withstand voltage: 2.5 kV, Pollution degree: 2
  • Dielectric strength: Test voltage: AC 1,500 V, > 100 MΩ(DC 500 V)
  • Interrupting capacity Icn: 0.63...2 A: 12 x IN; 2.5 ...8 A: 8 x IN, AC max. 50 A; 10 A: 6 x IN, AC
  • Interrupting capacity UL 1077: 0.63...10 A: 2,000 A AC 250 V; 0.63...8 A: 200 A DC 50 V
  • Degree of protection: Operating area: IP 40, Terminal area: IP 00
  • Vibration: 8 g (57-500 Hz)±0.61 mm (10-57 Hz)
  • Shock: 20 g (11 ms)
  • Corrosion: 48 hours at 5 % salt mist
  • Humidity: 96 hours at 95 % RH
  • Mass: approx. 5 g
  • Terminal design L1: solder pins 1.8x0.8 silver-plated
  • Terminal design L2/G1: solder pins 1x0.8 silver-plated
  • Terminal design P2: blade terminals A2.8-0.8 silver-plated
  • Actuator: manual re-set
  • Actuator colour: 01 black (-G1.. and -L1..), 02 white (-L2..)
  • Internal resistance: 0.63 A: 1.8 Ω, 0.8 A: 1.7 Ω, 1.3 A: 4.5 Ω, 2.5 A: 1 Ω, 4 A: 0.1 Ω, 5 A: 0.1 Ω, 6.3 A: 0.1 Ω, 8 A: 0.1 Ω, 10 A: 0.1 Ω

Buy the 1410-L210-L2F1-S02-5A E-T-A Single Pole Circuit Breaker | myMectronic

Purchase the E-T-A 1410-L210-L2F1-S02-5A circuit breaker securely and conveniently online.

Buy Now

Frequently Asked Questions

Where can I buy E-T-A 1410L210L2F1S025A?

You can click on the BUY or RFQ button to purchase 1410L210L2F1S025A from an authorized E-T-A distributor.

How do I troubleshoot issues or seek technical support for part 1410L210L2F1S025A?

You can download the 1410L210L2F1S025A datasheet or visit the E-T-A website for support.

Who is the manufacturer of 1410L210L2F1S025A?

E-T-A

Sponsored by