FLUKE 4328074 Infrared Thermometer

The Fluke 572-2 Infrared Thermometer is a robust and reliable tool for professionals working in demanding industrial settings such as power utility, metal refining, and petrochemical environments. It provides accurate, high-temperature, and high distance-to-spot measurements with a straightforward user interface and soft-key menus. The thermometer's ergonomic design, dual laser sighting, and compatibility with K-type thermocouples make it a versatile solution for a wide range of applications. Data storage and review capabilities, along with FlukeView Forms documenting software, further enhance its functionality.

Authorized Distributors
Part No:4328074
Stock:1
Inv Date:06-06-2026
Price: Unit price: $945.46
Buy/RFQ:
Part No:4328074
Stock:1
Inv Date:06-06-2026
Price: Unit price: $945.46
Buy/RFQ:

FLUKE 4328074 Infrared Thermometer Specifications:

  • Infrared temperature range: -30 °C to 900 °C (-22 °F to 1652 °F)
  • IR accuracy: ≥ 0 °C: ± 1°C or ± 1 % of the reading, whichever is greater ≥-10 °C to <0 °C: ± 2 °C < -10 °C: ± 3 °C ≥32 °F: ± 2 °F or ± 1 % of the reading, whichever is greater ≥14 °F to <32 °F: ± 4 °F <14 °F: ± 6 °F
  • IR Repeatability: ± 0.5 % of readingor ± 0.5 °C(± 1 °F), whichever isgreater
  • Display Resolution: 0.1 °C / 0.1 °F
  • Distance:Spot: 60:1
  • Minimum spot size: 19 mm
  • Laser sighting: Offset dual laser, output <1 mW
  • Spectral Response: 8μm to 14μm
  • Response Time(95 %): <500 ms
  • Emissivity: Digitally adjustable from 0.10 to 1.00 by0.01 or via built-in table of common materials
  • Hi/Low alarms: Audible and two-color visual
  • Min/Max/Avg/Dif: Yes
  • Switchable celsius and fahrenheit: Yes
  • Backlight: Two levels, normal and extra bright for darker environments
  • Probe input: K-type thermocouple
  • Trigger lock: Yes
  • Data storage: 99 points
  • Display: Dot matrix 98 x 96pixels with function menus
  • Communication: USB 2.0
  • K-type thermocouple input temperature range: -270 °C to 1372 °C(-454 °F to 2501 °F)
  • K-type thermocouple input accuracy: < -40 °C: ± (1 °C + 0.2 °/1 °C) ≥ -40 °C: ± 1 % or 1 °C, whichever is greater
  • K-type thermocouple resolution: 0.1 °C/0.1 °F
  • K-type thermocouple repeatability: ± 0.5 % of readingor ± 0.5 °C(± 1 °F), whichever isgreater
  • Measurement range (K-type thermocouple beadprobe): -40 °C to 260 °C (-40 °F to 500 °F)
  • Accuracy (K-type thermocouple): ± 1.1 °C (± 2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F)
  • Cable length: 1 m (40 in) K-type thermocouple cable
  • Operating temperature: 0 °C to 50 °C(32 °F to 122 °F)
  • Storage temperature: -20 °C to 60 °C(-4 °F to 140 °F)
  • Relative humidity: 10 % to 90 % RH non-condensing
  • Operating altitude: 2000 meters above mean sea level
  • Weight: 0.322 kg (0.7099 lb)
  • Power: 2 AA Batteries
  • Battery life: 8 hours with laser and backlight on; 100 hours with laser and backlight off

Buy the 4328074 FLUKE Infrared Thermometer | myMectronic

Purchase the Fluke 572-2 Infrared Thermometer securely and efficiently for reliable temperature measurement in your industrial applications.

Buy Now

Frequently Asked Questions

Where can I buy FLUKE 4328074?

You can click on the BUY or RFQ button to purchase 4328074 from an authorized FLUKE distributor.

How do I troubleshoot issues or seek technical support for part 4328074?

You can download the 4328074 datasheet or visit the FLUKE website for support.

Who is the manufacturer of 4328074?

FLUKE

FLUKE Part List

Browse and search other FLUKE parts, locate datasheets and stock

Sponsored by