Phoenix Contact 2907919 Type 3 Surge Protection Device The PHOENIX CONTACT PLT-SEC-T3-230-FM-UT is a Type 3 surge protection device engineered to safeguard industrial power supplies from voltage surges. This device, part of the PLT-SEC series, provides a crucial layer of protection, contributing to increased system uptime and reliability. It incorporates a status indicator and remote signaling functionality, enabling proactive monitoring and maintenance. The device is designed for single-phase power supply networks and offers a 5-year warranty when used in conjunction with PHOENIX CONTACT's QUINT 4 power supplies, highlighting the commitment to long-term performance and protection. Its pluggable connections simplify maintenance and testing, ensuring ease of use and efficient operation.
Authorized Distributors
Part No: 2907919
Stock: 5
Inv Date: 05-28-2026
Price: Unit price: $137.01
Part No: 2907919
Stock: 91
Inv Date: 05-28-2026
Price: Unit price: $178.74
Part No: 2907919
Stock: 144
Inv Date: 05-29-2026
Price: Unit price: $178.74
Part No: 2907919
Stock: 0
Inv Date: 05-28-2026
Price: Unit price: $195.08
Part No: 2907919
Stock: 24
Inv Date: 05-28-2026
Price: Unit price: $188.15
Part No: 2907919
Stock: 24
Inv Date: 05-28-2026
Price: Unit price: $188.15
Part No: 2907919
Stock: 2
Inv Date: 05-29-2026
Price: N/A
Buy/RFQ: RFQ
Phoenix Contact 2907919 Type 3 Surge Protection Device Specifications: Packing unit: 5 pc GTIN: 4055626257457 Height: 93.4 mm Width: 17.7 mm Depth: 74.5 mm Horizontal pitch: 1 Div. Degree of protection: IP20 Ambient temperature (operation): -40 °C ... 80 °C Ambient temperature (storage/transport): -40 °C ... 80 °C Altitude: ≤ 2000 m Permissible humidity (operation): 5 % ... 95 % Shock (operation): 30g Vibration (operation): 5g EN type: T2 / T3 IEC power supply system: TT, TN-S Number of ports: One Mode of protection: L-N, L-PE, N-PE Mounting type: DIN rail: 35 mm Color: light grey RAL 7035, traffic grey A RAL 7042 Housing material: PA 6.6-FR 20% GF, PA 6.6-FR Degree of pollution: 2 Flammability rating according to UL 94: V-0 Type: DIN rail module, two-section, divisible Number of positions: 2 Surge protection fault message: Optical, remote indicator contact Nominal voltage UN: 240 V AC (TN-S), 240 V AC (TT) Nominal frequency fN: 50 Hz (60 Hz) Maximum continuous voltage UC: 264 V AC Rated load current IL: 26 A Residual current IPE: ≤ 5 µA Nominal discharge current In(8/20) µs: 5 kA Standby power consumption PC: ≤ 26.4 mVA Reference test voltage UREF: 264 V AC Max. discharge current Imax(8/20) µs: 10 kA Combination wave UOC: 6 kV Voltage protection level Up(L-N): ≤ 1.25 kV Voltage protection level Up(L-PE): ≤ 1.4 kV Voltage protection level Up(N-PE): ≤ 1.4 kV TOV behavior at UT(L-N): 400 V AC, 457 V AC TOV behavior at UT(L-PE): 457 V AC Response time tA(L-N): ≤ 25 ns Response time tA(L-PE): ≤ 100 ns Response time tA(N-PE): ≤ 100 ns Short-circuit current rating ISCCR: 10 kA AC Max. backup fuse with branch wiring: 32 A Maximum backup fuse for through wiring: 25 A Short-circuit current rating ISCCR (DC): 0.25 kA Maximum continuous voltage UC (DC): 275 V AC, 240 V DC Mode of protection (DC): (DC+) - (DC-), (DC+/DC-) - PE IEC test classification: D1 Impulse durability (line-line): D1 - 500 A Impulse durability (line-earth): D1 - 500 A Pulse discharge current Iimp(10/350) µs (line-line): 0.5 kA Pulse discharge current Iimp(10/350) µs (line-earth): 0.5 kA Switching function: PDT contact Operating voltage (indicator): 250 V AC, 125 V DC Operating current (indicator): 0.5 A AC, 0.5 A DC Connection method: Screw connection Conductor cross section flexible: 0.2 mm² ... 2.5 mm² Conductor cross section solid: 0.2 mm² ... 4 mm² Conductor cross section AWG: 30 ... 12 Screw thread: M3 Tightening torque: 0.5 Nm Stripping length: 10 mm Maximum continuous operating voltage MCOV: 264 V AC, 240 V DC Nominal voltage (UL): 240 V DC Rated load current IL (UL): 20 A Mode of protection (UL): L-N, L-G, N-G, (DC+) - (DC-), (DC+) - G, (DC-) - G Power distribution system (UL): Single phase, DC Nominal frequency (UL): 50/60 Hz Measured limiting voltage MLV (L-N): 1150 V Measured limiting voltage MLV (L-G): 1180 V Measured limiting voltage MLV (N-G): 1180 V Nominal discharge current In (UL): 5 kA Operating voltage (UL indicator): 250 V AC, 12 V DC, 24 V DC, 48 V DC Tightening torque (UL indicator): 5 lbf-in. ... 7 lbf-in. Conductor cross section AWG (UL indicator): 30 ... 12 Conductor cross section AWG (UL connection): 16 ... 12 Tightening torque (UL connection): 4.4 lbf-in. Standards/specifications: IEC 61643-11 2011, EN 61643-11 2012 China RoHS: Environmentally Friendly Use Period = 50 Buy the 2907919 PHOENIX CONTACT Type 3 Surge Protection Device | myMectronic Secure your industrial power supply with the PHOENIX CONTACT PLT-SEC-T3-230-FM-UT – buy now for reliable surge protection.
Buy Now Frequently Asked Questions Where can I buy Phoenix Contact 2907919? You can click on the BUY or RFQ button to purchase 2907919 from an authorized Phoenix Contact distributor.
How do I troubleshoot issues or seek technical support for part 2907919? You can download the 2907919 datasheet or visit the Phoenix Contact website for support.
Who is the manufacturer of 2907919? Phoenix Contact
Phoenix Contact Part List Browse and search other Phoenix Contact parts, locate datasheets and stock Records per page: 12 25 50 All