The ABB BC7-30-10-01 mini contactor is a compact and reliable solution for controlling electrical loads in residential, commercial, and industrial settings. Its small size makes it ideal for applications where space is limited, while its robust design ensures dependable operation. The contactor is suitable for controlling single or three-phase loads up to 5.5 kW and switching control signals. Key features include a noiseless and hum-free coil, a switch position indication, and the integrated possibility for rail or wall mounting. It is designed for applications requiring reliability and space efficiency.

Authorized Distributors
Part No:BC7-30-10-01
Stock:5
Inv Date:06-02-2026
Price: Unit price: $107.27
Buy/RFQ:
Part No:BC7-30-10-01
Stock:19
Inv Date:06-01-2026
Price: Unit price: $106.07
Buy/RFQ:
Part No:BC7-30-10-01
Stock:10
Inv Date:06-01-2026
Price: Unit price: $94.51
Buy/RFQ:
Part No:BC7-30-10-01
Stock:10
Inv Date:06-01-2026
Price: Unit price: $94.51
Buy/RFQ:

ABB BC7301001 Mini Contactor 24VDC Specifications:

  • Extended Product Type: BC7-30-10-01
  • Product ID: GJL1313001R0101
  • EAN: 4013614150159
  • Catalog Description: BC7-30-10-01 Mini Contactor 24VDC
  • Number of Poles: 4
  • Mini Contactor Type: Mini Contactor
  • Rated Operational Voltage: 12 ... 240 V DC (Auxiliary Circuit), 12 ... 500 V AC/DC (Auxiliary Circuit), 12 ... 690 V AC/DC (Main Circuit), 690 V AC (Main Circuit)
  • Rated Frequency: Control Circuit DC, 60 Hz (Main Circuit), 50 Hz (Main Circuit), DC (Main Circuit)
  • Rated Impulse Withstand Voltage: 6 kV (Auxiliary Circuit), 6 kV (Main Circuit)
  • Rated Insulation Voltage: 690 V, acc. to UL/CSA 600 V
  • Number of Main Contacts NC: 0
  • Number of Main Contacts NO: 3
  • Rated Operational Current AC-1: 20 A (220 / 240 V, 40 °C), 16 A (220 / 240 V, 55 °C), 20 A (380 / 440 V, 40 °C), 16 A (380 / 440 V, 55 °C), 6 A (690 V, 40 °C), 6 A (690 V, 55 °C)
  • Rated Operational Power AC-3: (220 / 230 / 240 V) 3 kW, (400 V) 5.5 kW, (440 V) 5.5 kW, (500 V) 5.5 kW, (690 V) 3 kW
  • Rated Short-time Withstand Current: 96 A (at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s)
  • Number of Auxiliary Contacts NC: 0
  • Number of Auxiliary Contacts NO: 1
  • Rated Operational Current AC-15: (120 V) 4 A, (220 / 240 V) 4 A, (24 V) 4 A, (380 / 400 V) 3 A, (500 V) 2 A
  • Rated Operational Current DC-13: (110 V) 0.7 A, (220 / 240 V) 0.4 A, (24 V) 2.5 A
  • Conventional Free-air Thermal Current: 20 A
  • Rated Control Circuit Voltage: 24 V DC
  • Coil Operating Limits: 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
  • Degree of Protection: IP20 (Auxiliary Circuit Terminals), IP20 (Control Circuit Terminals), IP20 (Main Circuit Terminals)
  • Mechanical Durability: 10000000 cycle
  • Minimum Switching Capacity: 17 V, 5 mA
  • Maximum Electrical Switching Frequency: AC-1: 300 cycles per hour, AC-15: 600 cycles per hour, AC-3: 600 cycles per hour, DC-1: 600 cycles per hour, DC-13: 600 cycles per hour, DC-3: 600 cycles per hour
  • Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 1 ... 2.5 mm², Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm², Flexible 1/2x 1 ... 2.5 mm², Rigid 1/2x 1 ... 4 mm²
  • Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 1 ... 2.5 mm², Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm², Flexible 1/2x 1 ... 2.5 mm², Rigid 1/2x 1 ... 4 mm²
  • Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 1 ... 2.5 mm², Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm², Flexible 1/2x 1 ... 2.5 mm², Rigid 1/2x 1 ... 4 mm²
  • Wire Stripping Length: 9 mm (Auxiliary Circuit), 9 mm (Main Circuit)
  • Tightening Torque: 0.8 ... 1.1 N·m (Auxiliary Circuit), 0.8 ... 1.1 N·m (Control Circuit), 0.8 ... 1.1 N·m (Main Circuit)
  • Mounting on DIN Rail: TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715, TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
  • Power Loss: 2 W per pole
  • Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1
  • Ambient Air Temperature: Operation: -25 ... +55 °C, Storage: -40 ... +80 °C
  • Maximum Operating Altitude: 2000 m
  • Resistance to Shock: 11 ms Pulse 15g
  • Resistance to Vibrations: 5g / 5 ... 150 Hz
  • RoHS Status: Following EU Directive 2011/65/EC
  • Maximum Operating Voltage UL/CSA: 600 V AC (Main Circuit)
  • Full Load Amps Motor Use: (240 V AC) Single Phase 10 A, (440 ... 480 V AC) Three Phase 7.6 A
  • Horsepower Rating UL/CSA: (208 V AC) Three Phase 3 Hp, (220 ... 240 V AC) Single Phase 1.5 Hp, (220 ... 240 V AC) Three Phase 3 Hp, (440 ... 480 V AC) Three Phase 5 Hp, (550 ... 600 V AC) Three Phase 5 Hp
  • General Use Rating UL/CSA: 600 V AC 16 A

Buy the BC7-30-10-01 ABB Mini Contactor 24VDC | myMectronic

Purchase the ABB BC7-30-10-01 mini contactor securely and efficiently online.

Buy Now

Frequently Asked Questions

Where can I buy ABB BC7301001?

You can click on the BUY or RFQ button to purchase BC7301001 from an authorized ABB distributor.

How do I troubleshoot issues or seek technical support for part BC7301001?

You can download the BC7301001 datasheet or visit the ABB website for support.

Who is the manufacturer of BC7301001?

ABB

ABB Part List

Browse and search other ABB parts, locate datasheets and stock

Sponsored by